Who it’s for
Building managers, HVAC engineers, and environmental monitoring teams ask “is humidity drifting out of the comfort zone?” They combine trend data with a recognizable background for dedicated building management displays or reception screens.
What it does
A sensor averaging 65% this week, up from 45% last week, shows a +44% delta in red — humidity is climbing toward the Humid band. The chart below confirms the upward trend, displayed over the preset background image.
- Large current humidity value in the center, color-coded across five bands from Very Dry to Very Humid
- Percentage change vs. the previous period, with a colored arrow — red when humidity is rising, blue when falling
- Absolute humidity change in % shown below the delta percentage
- Time-series chart of humidity readings over the selected time window, averaged per interval
- Decorative background image bundled with the widget, with a white overlay that keeps the text readable
- Shows one sensor’s data; it does not compare multiple zones
How to set up
Data keys
| Key | Role | Type | Description |
|---|---|---|---|
humidity | Chart series | Timeseries | Relative humidity in %; drives the chart. The Latest, Delta percent, and Delta absolute overlays are automatically derived from this same key |
| Latest | Latest value | Timeseries | The headline figure above the chart. Its own color ranges are where the band colors are edited |
| Delta percent | Percentage change | Timeseries | Change against the previous period, as a percentage |
| Delta absolute | Absolute change | Timeseries | Change against the previous period, in the key’s own unit |
The widget ships with a simulated function datasource key labeled Humidity, so it draws random values until you point the datasource at a device and rename the key.
To point it at your own device: open the dashboard in edit mode, open the widget’s Datasources, pick the entity or entity alias, and replace the function key with the key your device reports.
If the key has never reported for the selected time window, the chart is empty and all overlays show no data.
Value ranges
| Range (%) | Level | Color |
|---|---|---|
| 0–20 | Very Dry | Red |
| 20–40 | Dry | Orange |
| 40–60 | Comfortable | Blue |
| 60–80 | Humid | Dark Blue |
| 80–100 | Very Humid | Deep Blue |
How to customize
- To swap the background image — open the widget settings and set Background to a different image or switch to a solid color.
- To adjust how much the background shows through — change the Overlay opacity; lower values reveal more of the image, higher values push it further back.
- To use your own humidity thresholds — edit the color ranges on the Latest data key; adjust the five default bands to match your facility’s targets.
- To hide or show the chart — toggle Show chart in the widget settings.
- To change the chart line color — set Chart color.
- To hide the entity name subtitle or the timestamp — turn off Show subtitle or Show date.
Tips
- A rising delta toward the Humid or Very Humid band can signal a ventilation or condensation problem. A falling delta toward Very Dry suggests heating or low outdoor humidity is drying the space out.
- If the background image reduces contrast, raise the Overlay opacity to keep the text readable from a distance.