Who it’s for
Facility managers, HVAC engineers, and building managers ask “what is the CO2 level in this space right now?” They need a compact, space-efficient card that fits into multi-room overview dashboards without dominating the layout.
What it does
A sensor reporting co2 = 720 ppm displays the reading in a horizontal card whose label and value sit side by side, color-coded by severity: green for Good (0–600 ppm), orange for Moderate (600–800 ppm), and red for High (above 800 ppm).
- Horizontal layout fits more rooms per row on a multi-zone indoor environment dashboard
- Live CO2 reading in ppm with automatic color coding across three severity bands
- Shows one sensor’s reading per widget; tile multiple widgets to monitor all rooms at a glance
How to set up
Data keys
| Key | Role | Type | Description |
|---|---|---|---|
co2 | Main value | Timeseries | CO2 concentration in ppm; change the key name to match your device’s telemetry key |
The widget ships with a simulated function datasource key labeled CO2 level, so it draws random values until you point the datasource at a device and rename the key.
To point it at your own device: open the dashboard in edit mode, open the widget’s Datasources, pick the entity or entity alias, and replace the function key with the key your device reports.
Value ranges
| Range (ppm) | Level | Color |
|---|---|---|
| 0–600 | Good | Green |
| 600–800 | Moderate | Orange |
| 800+ | High | Red |
How to customize
- To change the severity thresholds — edit Icon color ranges and Value color ranges; set the same boundaries in both so the icon and the number always agree.
- To change the band colors — edit the color of each range in Icon color ranges and Value color ranges.
- To rename the units label — change the Units field in the widget settings if needed.
Tips
- Use the horizontal layout to fit more rooms per row when building a whole-floor or whole-building CO2 overview; pair with the standard card for rooms that frequently hit the High band and warrant closer attention.
- Placing horizontal cards for CO2, temperature, and humidity side by side on the same row lets facility staff quickly identify rooms with combined comfort issues that need HVAC attention.
- For demand-controlled ventilation, a row of horizontal CO2 cards lets operators see at a glance which zones are occupied and driving up CO2 so they can manually boost supply air if the automation is slow to respond.