Indoor PM2.5 card
Who it’s for
Facility managers, building managers, and indoor air quality specialists ask “what is the PM2.5 fine particulate level in this space right now?” They need an instant, color-coded reading to assess whether combustion particles from cooking, printing, or nearby traffic are affecting the indoor environment.
What it does
A sensor reporting pm2.5 = 18 µg/m³ displays the reading on a card with the value color-coded by severity: light green for Good (0–35 µg/m³), orange for Moderate (35–75 µg/m³), and red for High (above 75 µg/m³).
- Live PM2.5 reading in µg/m³ with automatic color coding across three severity bands
- Instant severity signal lets staff act on fine particulate exceedances without interpreting raw numbers
- Shows one sensor’s reading per widget; tile multiple widgets to monitor all zones at a glance
How to set up
Data keys
| Key | Role | Type | Description |
|---|---|---|---|
pm2.5 | Main value | Timeseries | PM2.5 concentration in µg/m³; change the key name to match your device’s telemetry key |
The widget ships with a simulated function datasource key labeled PM2.5, so it draws random values until you point the datasource at a device and rename the key.
To point it at your own device: open the dashboard in edit mode, open the widget’s Datasources, pick the entity or entity alias, and replace the function key with the key your device reports.
Value ranges
| Range (µg/m³) | Level | Color |
|---|---|---|
| 0–35 | Good | Light Green |
| 35–75 | Moderate | Orange |
| 75+ | High | Red |
How to customize
- To change the severity thresholds — edit Icon color ranges and Value color ranges; set the same boundaries in both so the icon and the number always agree.
- To change the band colors — edit the color of each range in Icon color ranges and Value color ranges.
- To rename the units label — change the Units field in the widget settings if needed.
Tips
- PM2.5 particles (smaller than 2.5 µm) penetrate deeper into the lungs than PM10, so a Moderate PM2.5 reading warrants faster intervention — particularly in spaces occupied by children, the elderly, or people with respiratory conditions.
- If PM2.5 is elevated while PM10 is normal, the source is likely fine combustion (candles, cooking, 3D printing filament) rather than coarse dust — a distinction that determines whether opening a window or eliminating the source is the right response.
- For health and safety compliance in laboratories and print rooms, set the High threshold to 35 µg/m³ (WHO guideline level) to trigger alerts before the default 75 µg/m³ moderate-band upper limit.
Share Your Widget with the Community
Built a custom widget? Export it as a JSON from ThingsBoard and publish it to the IoT Hub through a simple 4-step wizard (Upload, Listing, Readme, Review & Submit). Share it with thousands of ThingsBoard developers worldwide and get featured in the catalog.