HP Bottom Tee Connector

HP Bottom tee connector SCADA symbol

The HP Bottom tee connector widget renders a T-shaped connector with openings on the left, right, and bottom — a horizontal run with a downward branch. Each arm carries its own animated fluid flow stripe that can be shown or hidden and controlled in direction and speed from live device data.

Use it wherever a main pipeline splits off a downward branch or a drain line — for example, routing a horizontal supply line to a downward-facing outlet, bypass, or drain in HVAC, water treatment, industrial automation, or building management systems.

  • Display a T-shaped connector with openings at the left, right, and bottom.
  • Independently show or hide an animated fluid flow stripe on each arm (left, right, bottom) based on device state.
  • Control the flow direction (forward or reverse) on each arm from live device data.
  • Control the flow animation speed on each arm from live device data.
  • Receive state data from device attributes, time series, alarm status, or dashboard state.
  1. Open the dashboard and switch to edit mode.
  2. Click Add widget at the top, or the Add new widget icon in the center of the screen.
  3. Open the General high-performance SCADA symbols widget bundle.
  4. Select HP Bottom tee connector.
  5. Configure the widget settings, then click Add.

The widget connects to a single data source: either a Device or an Entity alias that resolves to a device. This device provides the attribute or telemetry values used to drive the widget’s visual state.

The SCADA symbol defines the visual shape of the widget. The HP Bottom tee connector widget has a pre-selected symbol from the General high-performance SCADA symbols bundle. To use a different symbol, click Browse SCADA symbol from gallery and choose one from the library, or upload your own.

Behavior parameters define what the widget displays, driven by real-time data from the connected device. The three arms — Left connector, Right connector, and Bottom connector — are configured independently. Each arm has the same three parameters.

Parameter Default Description
Flow presence Absent Whether the animated fluid flow stripe is shown on the left arm. See Presence and direction configuration.
Flow direction Forward Direction of the animated flow on the left arm. See Presence and direction configuration.
Flow animation speed 1 Speed of the flow animation on the left arm. 1 is normal speed; 0 disables animation; values above 1 slow the animation; values below 1 speed it up. See Flow animation speed configuration.
Parameter Default Description
Flow presence Absent Whether the animated fluid flow stripe is shown on the right arm. See Presence and direction configuration.
Flow direction Forward Direction of the animated flow on the right arm. See Presence and direction configuration.
Flow animation speed 1 Speed of the flow animation on the right arm. See Flow animation speed configuration.
Parameter Default Description
Flow presence Absent Whether the animated fluid flow stripe is shown on the bottom arm. See Presence and direction configuration.
Flow direction Forward Direction of the animated flow on the bottom arm. See Presence and direction configuration.
Flow animation speed 1 Speed of the flow animation on the bottom arm. See Flow animation speed configuration.

Applies to Flow presence and Flow direction on each arm. Click the edit icon next to a parameter to open its configuration dialog. When Action is set to Do nothing, select a fixed value:

Parameter Value
Flow presence Present or Absent
Flow direction Forward or Reverse

For all other actions, the configuration dialog includes these options:

  • Execute RPC

    Read the parameter value from an RPC response.

    Parameter Description
    Method RPC method to call, like getFlowState.
    Action result converter None — parameter is activated when the result matches the value you specify; Function — parameter is activated when your f(data) returns true.
    ‘Present’/‘Forward’ when result is The value or condition that activates the present or forward state.
    RPC request timeout (ms) How long to wait for a device response before timing out (Advanced settings).
    RPC request persistent Stores and retries the command until the device comes online (Advanced settings).
  • Get attribute

    Read the parameter value from a device attribute.

    Parameter Description
    Attribute scope Where the attribute is stored: Any, Client, Server, or Shared.
    Attribute key Attribute name to read, like flowPresent or flowDirection.
    Action result converter None — parameter is activated when the attribute equals the value you specify; Function — parameter is activated when your f(data) returns true.
    ‘Present’/‘Forward’ when result is The value or condition that activates the present or forward state.
  • Get time series

    Read the parameter value from the latest telemetry reading.

    Parameter Description
    Time series key Telemetry key to monitor, like flowPresent.
    Action result converter None — parameter is activated when the telemetry value equals what you specify; Function — parameter is activated when your f(data) returns true.
    ‘Present’/‘Forward’ when result is The value or condition that activates the present or forward state.
  • Get alarm status

    Activate the present or forward state when a specific alarm is active on the device.

    Parameter Description
    Alarm severity Which severity levels trigger the active state: Critical, Major, Minor, Warning, or Indeterminate.
    Alarm types Any alarm, or a specific alarm type.
  • Get dashboard state id

    Activate the present or forward state based on which dashboard state is currently open.

    Parameter Description
    Action result converter None — parameter is activated when the state name matches the text you enter; Function — parameter is activated when your f(data) returns true.
    ‘Present’/‘Forward’ when result is The state name or condition that activates the present or forward state.
  • Get dashboard state object

    Activate the present or forward state using the full dashboard state context; use this when you need to evaluate multiple state parameters at once.

    Parameter Description
    Parse value function A f(data) function that receives the current dashboard state object. Use data.id to read the active state name, or data.params to inspect state parameters.
    ‘Present’/‘Forward’ when result is The expected type and value that activates the present or forward state. Choose String, Integer, Double, Boolean (then select True or False), or JSON.

Applies to Flow animation speed on each arm. Click the edit icon next to the parameter to open its configuration dialog. When Action is set to Do nothing, enter a fixed numeric speed value.

For all other actions, the configuration dialog works the same way:

  • Execute RPC

    Read the speed value from an RPC response.

    Parameter Description
    Method RPC method to call, like getFlowSpeed.
    Action result converter None — uses the result value directly; Function — returns the value from your f(data) function.
    RPC request timeout (ms) How long to wait for a device response before timing out (Advanced settings).
    RPC request persistent Stores and retries the command until the device comes online (Advanced settings).
  • Get attribute

    Read the speed value from a device attribute.

    Parameter Description
    Attribute scope Where the attribute is stored: Any, Client, Server, or Shared.
    Attribute key Attribute name to read, like flowSpeed.
    Action result converter None — uses the attribute value directly; Function — returns the value from your f(data) function.
  • Get time series

    Read the speed value from the latest telemetry reading.

    Parameter Description
    Time series key Telemetry key to monitor, like flowSpeed.
    Action result converter None — uses the telemetry value directly; Function — returns the value from your f(data) function.
  • Get alarm status

    Set the speed value based on alarm activity on the device.

    Parameter Description
    Alarm severity Which severity levels trigger the active state: Critical, Major, Minor, Warning, or Indeterminate.
    Alarm types Any alarm, or a specific alarm type.
  • Get dashboard state id

    Set the speed value based on which dashboard state is currently open.

    Parameter Description
    Action result converter None — uses the state name directly; Function — returns the value from your f(data) function.
  • Get dashboard state object

    Set the speed value using the full dashboard state context; use this when you need to evaluate multiple state parameters at once.

    Parameter Description
    Parse value function A f(data) function that receives the current dashboard state object. Use data.id to read the active state name, or data.params to inspect state parameters.

The Appearance section controls the widget title, the connector line style, and the flow animation stripe style.

Setting Default Description
Title HP Bottom tee connector Widget title displayed in the header. Supports entityName and entityLabel variables.
Card icon — Icon shown in the widget header. Configure its size and color.
Line 6 px, black Thickness and color of the main connector line.

Flow subsection — controls the appearance of the animated fluid flow stripe on all arms:

Setting Default Description
Line 4 px, light blue Thickness and color of the flow animation stripe.
Line style Dash 10 px, Gap 10 px Dash and gap lengths of the flow stripe. For smooth looping, use values that divide evenly into 100.
Dash cap Butt End cap style for each dash segment: Butt (flat), Round (rounded ends), or Square (flat with half-width extension).

The Card appearance section controls the widget container style.

Setting Default Description
Background Transparent Card background color.
Show card buttons Fullscreen Buttons shown on the card when hovered.
Card border radius 0px Rounding of card corners.
Card padding 12px Inner spacing between the card edge and widget content.

Flow animation does not run on an arm

Cause Solution
Flow presence for that arm is Do nothing with value set to Absent Open the Flow presence edit dialog for the affected arm and set the value to Present, or configure it to read from a device attribute or time series key.
Flow animation speed for that arm is 0 Open the Flow animation speed edit dialog for the affected arm and set a non-zero value.

Flow animation runs in the wrong direction on an arm

Cause Solution
Flow direction for that arm is set to the opposite value Open the Flow direction edit dialog for the affected arm and switch between Forward and Reverse, or configure it to read the direction from a device attribute or time series key.
IoT Hub

Install the Swimming pool SCADA system Solution Template from the ThingsBoard IoT Hub to see this widget running in a complete, ready-to-use dashboard.

Browse the catalog

This widget is used in the following ready-made solution template built on the General high-performance SCADA symbols bundle:

  • SCADA Swimming pool — a complete swimming pool monitoring dashboard that uses the HP Bottom tee connector to represent branching flow paths between diagram elements.