Small Right Motor Pump

The Small right motor pump widget renders a compact motor pump symbol with the pipe connector oriented to the right side. Use it in space-constrained layouts where a smaller footprint is needed.
This widget belongs to the Traditional SCADA fluid system bundle — a collection of pipe segments, fittings, valves, pumps, and gauges designed for building fluid system diagrams on ThingsBoard dashboards. It represents a motor pump with color-coded running, warning, and critical states.
Key capabilities
Section titled “Key capabilities”- Indicate pump running state with a configurable running color.
- Indicate warning and critical states with configurable colors.
- Animate a blinking effect when the pump is in critical state.
- Trigger a dashboard action when the widget symbol is clicked.
- Receive state data from device attributes, time series, alarm status, or dashboard state.
Target device
Section titled “Target device”The widget connects to a single data source: either a Device or an Entity alias that resolves to a device. This device provides the telemetry or attribute values used to drive the widget’s visual state.
SCADA symbol
Section titled “SCADA symbol”The SCADA symbol defines the visual shape of the widget. Each motor pump widget has a pre-selected symbol from the Traditional SCADA fluid system bundle. To use a different symbol, click Browse SCADA symbol from gallery and choose one from the library, or upload your own.
Behavior
Section titled “Behavior”Behavior parameters define what the widget displays, driven by real-time data from the connected device. Each parameter supports the same set of actions — see Behavior configuration for the full list.
| Parameter | Default | Values | Description |
|---|---|---|---|
| Running | Use attribute 'running' | True, False | Whether the pump is currently running. |
| Warning state | Use alarm status | True, False | Whether the pump is in warning state. |
| Critical state | Use alarm status | True, False | Whether the pump is in critical state. |
| Critical state animation | False | True, False | Whether to enable blinking animation when the pump is in critical state. |
| On click | Do nothing | — | Action triggered when the user clicks the widget symbol. |
On click
Section titled “On click”Defines what happens when the user clicks the SCADA symbol on the dashboard. Select one action type from the list below.
-
Do nothing
The symbol is clickable but performs no action. Use while testing styles or as a placeholder.
-
Navigate to new dashboard state
Switches to a different view within the same dashboard, like opening a device details screen.
Parameter Description Target dashboard state The state to open (required). Open right dashboard layout (mobile view) Opens a side panel instead of replacing the view (mobile only). Set entity from widget Passes the current entity to the target state. State entity parameter name The key the entity is passed under. Dashboard state display option Normal (same view), In separate dialog (popup), or In popover (inline overlay). -
Update current dashboard state
Updates the context of the current view, like switching the selected device, without navigating away.
Parameter Description Target dashboard state The state to switch to (optional). Open right dashboard layout (mobile view) Opens a side panel on mobile. Set entity from widget Passes the current entity to the updated state. State entity parameter name The key the entity is passed under. -
Navigate to other dashboard
Opens a completely different dashboard, like jumping from this system view to a global alarms view.
Parameter Description Target dashboard The dashboard to open (required). Target dashboard state The specific view to open within that dashboard. Open in a new browser tab Opens the dashboard without leaving the current page. Set entity from widget Passes the current entity to the other dashboard. State entity parameter name The key the entity is passed under. -
Custom action
Runs custom JavaScript on click to implement any behavior not covered by the built-in options. Use it to make HTTP requests, open custom dialogs, call other widget APIs, or interact with external services. The function receives:
$event,widgetContext,entityId,entityName,additionalParams,entityLabel. -
Custom action (with HTML template)
Same as Custom action, but also renders a custom HTML panel or dialog when the symbol is clicked. The function receives an additional
htmlTemplateparameter:$event,widgetContext,entityId,entityName,htmlTemplate,additionalParams,entityLabel.Parameter Description Resources External scripts and styles loaded before the action runs. CSS Styling for the HTML template. HTML Layout of the rendered dialog or panel. JS Action logic. -
Mobile action
Triggers a native device feature inside a ThingsBoard mobile app, like the camera or QR scanner.
Parameter Description Mobile action type Take picture from gallery, Take photo, Open map directions, Open map location, Scan QR Code, Make phone call, Get phone location, Take screenshot, or Device provision. -
Open URL
Opens a website or external link when clicked.
Parameter Description URL The address to open (required). Open in a new browser tab Keeps the current dashboard open while opening the link.
Behavior configuration
Section titled “Behavior configuration”To configure a parameter, click its edit icon. When Action is set to Do nothing, the Value options depend on which parameter you are configuring:
| Parameter | Value |
|---|---|
| Running | True or False |
| Warning state | True or False |
| Critical state | True or False |
| Critical state animation | True or False |
For all other actions, the configuration dialog works the same way regardless of which parameter you are editing:
-
Execute RPC
Read the parameter value from an RPC response.
Parameter Description Method RPC method to call, like getStateorgetPumpStatus.Action result converter None — parameter is activated when the result matches the value you specify; Function — parameter is activated when your f(data)returnstrue.’[parameter]’ when result is The value or condition that activates this parameter. RPC request timeout (ms) How long to wait for a device response before timing out (Advanced settings). RPC request persistent Stores and retries the command until the device comes online (Advanced settings). -
Get attribute
Read the parameter value from a device attribute.
Parameter Description Attribute scope Where the attribute is stored: Any, Client, Server, or Shared. Attribute key Attribute name to read, like runningorpumpState.Action result converter None — parameter is activated when the attribute equals the value you specify; Function — parameter is activated when your f(data)returnstrue.’[parameter]’ when result is The value or condition that activates this parameter. -
Get time series
Read the parameter value from the latest telemetry reading.
Parameter Description Time series key Telemetry key to monitor, like pumpRunningorstatus.Action result converter None — parameter is activated when the telemetry value equals what you specify; Function — parameter is activated when your f(data)returnstrue.’[parameter]’ when result is The value or condition that activates this parameter. -
Get alarm status
Activate the parameter when a specific alarm is active on the device.
Parameter Description Alarm severity Which severity levels trigger the active state: Critical, Major, Minor, Warning, or Indeterminate. Alarm types Any alarm, or a specific alarm type. -
Get dashboard state id
Activate the parameter based on which dashboard state is currently open.
Parameter Description Action result converter None — parameter is activated when the state name matches the text you enter; Function — parameter is activated when your f(data)returnstrue.’[parameter]’ when result is The state name or condition that activates this parameter. -
Get dashboard state object
Activate the parameter using the full dashboard state context; use this when you need to evaluate multiple state parameters at once.
Parameter Description Parse value function Write a f(data)function that returns the parameter value.
Appearance
Section titled “Appearance”The Appearance section controls the widget title and pump state colors.
| Setting | Default | Description |
|---|---|---|
| Title | Widget name | Widget title displayed in the header. Supports entityName and entityLabel variables. |
| Card icon | — | Icon shown in the widget header. Configure its size and color. |
| Running color | Green | Pump color when in the running state. |
| Stopped color | Gray | Pump color when stopped (not running). |
| Warning color | Orange | Pump color when in warning state. |
| Critical color | Red | Pump color when in critical state. |
Card appearance
Section titled “Card appearance”The Card appearance section controls the widget container style.
| Setting | Default | Description |
|---|---|---|
| Background | Transparent | Card background color. |
| Show card buttons | Fullscreen | Buttons shown on the card when hovered. |
| Card border radius | 0px | Rounding of card corners. |
| Card padding | 12px | Inner spacing between the card edge and widget content. |
Troubleshooting
Section titled “Troubleshooting”Pump color does not change when running
| Cause | Solution |
|---|---|
Running action is set to Do nothing and value is False | Open the Running edit dialog, set the correct Action, and specify the attribute key. |
| Target device is not connected | Confirm that the selected device is online and actively sending data. |
Warning or critical color does not appear
| Cause | Solution |
|---|---|
Warning state or Critical state action is Do nothing and value is False | Configure the state parameter to read from an alarm status or a device attribute. |
| Alarm is not active on the device | Confirm that the device has an active alarm of the expected severity. |
Solution templates
Section titled “Solution templates”These widgets are used in the following ready-made solution templates built on the Traditional SCADA fluid system bundle:
- SCADA Swimming pool — a complete swimming pool monitoring dashboard built with pipe, pump, valve, and gauge widgets from the Traditional SCADA fluid system bundle.